Storage tanks fail in slow, predictable ways — floor plate corrosion, shell thinning, settlement, and roof and appurtenance deterioration. API 653 exists because each of those needs looking at on a different interval, with a different method.
In-service and out-of-service scope
An in-service external inspection covers shell, external coating, foundation, appurtenances and visible settlement without taking the tank out of operation. An out-of-service internal inspection additionally covers floor plate condition, which is where most integrity risk actually sits.
Positioning on our scope
We perform inspection, measurement and condition assessment aligned to API 653 methodology and report findings against it. Where a formal API-certified inspector's stamp or a statutory German tank certification is required, we will tell you plainly and coordinate with the appropriate certified body rather than overstate our scope.
Scope of work
- External in-service tank condition inspection
- Shell course ultrasonic thickness measurement
- Floor plate condition assessment (out-of-service)
- Roof, appurtenance, nozzle and manway inspection
- Foundation and settlement survey
- Condition report with prioritised repair recommendations
Request this service
Tell us the item, the applicable standard and the location. We confirm scope, inspector and price within one working day.
Standards referenced
- Tank inspection, repair and reconstructionAPI 653
- Welded tanks for oil storageAPI 650
- Ultrasonic thickness measurementISO 16809
Direct line
Coverage
Berlin / Brandenburg, nationwide Germany, EU and worldwide on request.
NDT & Asset Integrity
Finding what a visual check cannot — in welds, vessels, tanks and piping.

Non-Destructive Testing (NDT)
UT, MT, PT, RT, VT and leak testing by ISO 9712-qualified technicians, with the method matched to the def…

Welding Inspection
Visual and procedural weld inspection, WPS and PQR review and welder qualification oversight, to ISO 3834…

Corrosion & Erosion Assessment
Wall thickness mapping, coating condition assessment and remaining-life input for in-service equipment.…
Get a scoped quote within one working day.
Reports signed by the inspector who was on site, issued in German or English within 48 hours.